INT4SAN in practice — a collection store in Venice

In 2021–2022 the system was studied in the Fondazione Querini store — on the ground floor, with one wall directly bordering a canal.

01 / Results

What was observed after start-up?

−69.7%
Total microbial load
373 → 113 CFU/m³ · point 03
−94.1%
Xerophilic fungi
340 → 20 CFU/m³ · point 03
70% → 58%
Relative humidity
selected sensor
35 days
Observation period
20.01 – 24.02.2022

How was the study carried out?

First measurements were taken on 20 December 2021. The device was switched on on 20 January 2022 and air was sampled again on 24 February 2022. Four points inside two rooms and one outdoor control point were measured; temperature and humidity were also monitored.

What do the results mean?

The study indicates that INT4SAN can support better microbiological air quality and reduce excess humidity. The largest reduction in xerophilic fungi was found at the point closest to the device.

Values calculated from the report's charts. The report also notes no significant improvement for bacteria. These are observations from a specific study, not a guarantee of identical results in every room.

Download the report (EN, PDF) ↓

02 / Study timeline

20.12.2021
Inspection and baseline sampling
20.01.2022
INT4SAN switched on
24.02.2022
Second sampling

03 / Study conditions

Site
The “Paradiso” store of Fondazione Querini in Venice — two symmetrical rooms joined by a hall with no door.
Challenge
Ground floor, north-east wall directly on the canal; no humidity control devices were running at inspection.
Collection
Items on shelves about 30 cm above the floor, with insulating polyethylene sheets between walls and shelving.
Device
Placed in Room 2 near the north-east wall. Archive staff routines did not change during the study.
Method
SAS-IAQ sampler, active aspiration of 150 L of air at each point, media for fungi and aerobic heterotrophic bacteria.